ARAG BRAVO DSB User Manual

Page 6

Advertising
background image

3.1

Control panel key

A

= on/off switch

B

= status indicator of the section valve

(the identification number depends on the section number assembled on the machine)
• Red: valve opening command
• Green: valve closing command
• Off: command is not connected

c

= status indicator of the regulation valve

• Red: increase pressure command
• Green: decrease pressure command
• Off: no command or not connected

d

= status indicator of the general valve

• Red: valve opening command
• Green: valve closing command
• Off: command is not connected

e

= auxiliary power connector

f

= low battery warning alarm

g

= warning signal of power polarity inversion

h

= connector to “T” cabling

i

= potentiometers for regulating signals generated by the simulator

Turn the potentiometers anti-clockwise to stop signal generation

L

= selection of signals to be sent to/from the computer

Moving the switches up sends the signals coming from the sensors installed on the spraying system
to the Bravo computers;
moving the switches down sends the signals generated by the Bravo DSB simulator to the Bravo
computers.

M

= status indicator of the signals coming from the transducers and from the sensors

installed on the spraying system
See table 4 - correspondence between symbols - signal typology

n

= automatic functioning mode selector

Bravo DSB enables the simulation of the system working during automatic regulation (carried out
by computers equipped with this function)
• function activated --> green LED on (

FEEDBACK ON

)

• function disabled --> green LED off (

FEEDBACK ON

)

(in this case using potentiometers “

I” you obtain manual regulation)

o

= regulation valve simulator

The LED bar simulates the position of the pivot of the regulating valve during automatic function
mode: the system simulates the functioning of the regulation valve when used as a dump valve,
which is its typical application in case of plunger or diaphragm pumps; when the regulation valve
is used as a 2-ways valve (typical application with centrifugal pumps), the functioning of the LED
bar will be inverted

P

= status indicator of the foam marker

• L: left side
• R: right side

6

Advertising
This manual is related to the following products: