Eneo HDD-2030PTZ1080 User Manual

Page 20

Advertising
background image

9. Select “SAVE AND EXIT” and push the Joystick to the right or press the IRIS Open key. Press

the ESC or IRIS Close key to exit the program without saving.

You can expand the Tour sequence by calling other programmed Tours.

NOTE: The speed applies in the vector mode only.

NOTE: In the Tour mode, in conjunction with Preset and Auto Scan, you can make the

camera travel from a Preset position to another Preset position at a specific speed.

Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at Preset 002, ends at

Preset 003, Auto Scan 02 starts at Preset 005, ends at Preset 006;
Tour 001, 002, A01, 004, A02.

1

 2 2~3  4  5~6, repeat

where

 : Quick move, ~ : Programmed speed

To change the dwell time of the Preset in the Tour:

Use the Joystick to move the cursor to a stored Preset position.
By pressing the PRST key, the camera will move to the stored Preset view and the cursor moves
to the dwell time field.
After changing the dwell time, press the PRST key and the cursor moves to the Preset number.

To assign the functions other than Preset in the Tour when the function key is not
existed:

Use the Joystick to move the cursor to a stored Preset position.
Pressing the CTRL or IRIS Open key will change the Preset number to other function (Auto Scan,
Pattern, Tour or Preset) with the first programmed number.
To change the number, twist the Joystick or press the Tele or Wide key.

15

Advertising
This manual is related to the following products: