Troubleshooting the PSR300-12A series/PSR300-12D series

The power module LEDs are steady green while the power supply system is correctly operating. If the

LEDs behave in any other way, verify the following items:

The power module is switched on.

The switch power cord is correctly connected.

The power source meets the requirement.

The operating temperature of the switch is normal and proper ventilation is ensured for the power
module.

NOTE:

If the problem persists, contact your local sales agent or service engineer.

To replace a hot swappable power module, see “

Installing/Removing a power module

.”

Troubleshooting the
LSVM1AC650/LSVM1DC650/LSVM1AC300/LSVM1DC30

0

The LEDs on the power module are steady green (active) or blinking green (standby) while the power

supply system is correctly operating. If the LEDs behave in any other way, check the following items:

The switch power cord is correctly connected.

The power source meets the requirement.

The operating temperature of the switch is in the normal range and the power module has good
ventilation.

NOTE:

If the problem persists, contact your local sales agent or service engineer.

To replace a hot swappable power module, see “

Installing/Removing a power module

.”

OAP card failure

This section applies to the S5820X-28C switch.

Failure of the OAP card in the OAP card slot

You can look at the SLOT3 LED on the front panel of the switch and the LED on the OAP card to identify
the failure of the OAP card in the OAP card slot.

For more information about the SLOT3 LED, see

Table 15

.

For more information about the LEDs on the OAP card, see H3C OAP Cards User Manual.

The OAP card LED (SLOT3) is steady green while the OAP card is correctly operating. If the LED behaves

in any other way, check the following items: