Cooling, Esd prevention – H3C Technologies H3C SecPath F5000-A5 Firewall User Manual

Page 14

Advertising
background image

4

Cooling

The F5000-A5 firewalls adopt left to right airflow for heat dissipation. Plan the installation site for
adequate ventilation.

•

Leave at least 10 cm (3.94 in) of clearance at the inlet and outlet air vents.

•

The installation site has a good cooling system.

Figure 1 Airflow through the F5000-A5 chassis

ESD prevention

CAUTION:
•

Check the resistance of the ESD wrist strap for safety. The resistance reading should be in the range of
1 to 10 megohm (Mohm) between human body and the ground.

•

The F5000-A5 does not provide any ESD wrist strap. Prepare it yourself.

To prevent electrostatic discharge (ESD), follow these guidelines:

•

Make sure the firewall and rack are correctly grounded.

•

An anti-static floor is installed and correctly grounded.

•

Maintain the humidity and temperature at a compliant range in the equipment room. For more
information, see "

Temperature and humidity

."

•

Always wear an ESD wrist strap and ESD cloth when touching a circuit board, interface module, or
transceiver module.