Grass Valley 7600REF User Manual

Page 23

Advertising
background image

7600 SD/HD/MHD-REF — Instruction Manual

23

Installation

GPI Outputs 1 and 2

The General Purpose Interface (GPI) outputs 1 and 2 are configured in soft-
ware using the menus described in

GPI Outputs 1 and 2 on page 23

to

provide any of the following functions:

•

Loss of genlock input

•

Loss of external 10MHz reference

•

Line lock error

•

Field lock error

•

Subcarrier lock error

•

Illegal input ScH

•

Diagnostic state alert

•

Currently locked to external 10MHz

•

Currently locked to external genlock

•

Currently internal/freerun mode

The GPI outputs are single-ended open collector outputs with a
50V/200mA rating not to exceed 600 mW. The two GPI outputs are pin 17
and pin 21 as listed in

Table 1 on page 21

. It is intended that the GPO be

activated when one or more of the above conditions is true (for example,
loss of genlock input and/or line lock error).

To use an output, a load should be connected between the output and an
external power supply, with the negative end of the power supply con-
nected back to the ground pin on the 25 pin Sub-D connector.

As an alternate to an external power supply, a +12V, 300mA feed is avail-
able on pin 10 of the Sub-D connector.

Figure 3. Connection to GPI Outputs

7600REF

Power Supply

+

_

Load

GPO

Advertising