Grass Valley 8943RDA User Manual
Page 58

Use
this
link
58
8943RDA/-D/-DFR — Instruction Manual
Configuration
8943RDA-D Settings Web Page
The Settings web page for the 8943RDA-D (
) provides selection of
the input operating mode for Ch 1 and Ch 2 and the input source to output
pair mapping.
Coax Inputs –
select the operating mode for
Ch 1 - J9
and
Ch 2 - J10
. The oper-
ating mode choices are listed below:
•
Auto Reclock/Bypass,
•
Auto Reclock/Mute,
•
3G 2970M,
•
HD 1485M,
•
SD 270M,
•
Manual Bypass HD/3G, or
•
Manual Bypass SD.
For a full description of each of these modes, refer to the Modes summary
in
Input Operating Modes on page 28
.
The Coax Inputs display will also report the
Rate Detected
and the
Signal State
.
If the output signal is
Not Present
and has been muted, the display will also
report
Mute
as shown in the setting for CH1 in
Outputs
– set the input to output mapping for the module with the radio
buttons in the Output Selection controls. Refer to
for an explanation of input to output mapping.