Camera Unit Connectors

Camera Remote: Data 1 (Camera Control) and Data 3 (RS232)

Camera Unit

Hirose 10-pin Female

Format select (Pin 5)

Floating for RS-422 or

TTL

Tie to GND for RS-232

Tie to +12VDC (pin 15)

for RS-485

Pin Function

1

+12VDC Input Power

(also Camera Control Data Format Select Bias)

2

12VDC Input Power – Ground

3

Camera Control Data (+) Input

or Bi-directional Camera Control Data I/O

4

232 Data Input (Data 3)

5

Camera Control Data Format Select (see choices to left)

6

Camera Control Data (-) Output

7

Ground (Camera Control Data Shields, 232 Data Common)

8

232 Data Output (Data 3)

9

Camera Control Data (-) Input

10

Camera Control Data (+) Output

Camera Unit Camera Remote Connector Wiring

(Mating connector - Hirose HR10A-10P-10P)

Camera Unit Production/Signal

Camera Unit #9

DB15HD Female

Format select (Pin 10)

Floating for RS-422 or

TTL

Tied to GND for RS-232

Tied to +12VDC for RS-

485

Pin Function

1

Data 2 -422 Out

2

Data 2 -422 In, -485 I/O

3

Intercom Microphone Trigger

4

GPI In

5

GND

6

Data 2 232 OUT, +422 Out

7

GND

8

Data 2 232 In, +422 In, +485 I/O

9

Not Used

10

Data2 Format (see choices to the left)

11

GPI 2 OUT B (Green)

12

GPI 2 OUT A (Green)

13

GPI 1 OUT B (Red)

14

GPI 1 OUT A (Red)

15

+12VDC (100mA max) Bias for Format

Camera Unit Production DB15HD Connector Wiring