SERVICE MANUAL TNC 306/360
Page 26
HEIDENHAIN Service
6.4.2 Connectors on the Flat Screen BF 110
6.4.2.1 Connector Desgination
X1
X2
+
-
6.4.2.2 Pin Layout
X1: Power Supply for the Flat Screen
Terminal block (pluggable), 2-pin
Pin No.
Signal
-
0V supply
+
+ 24V supply
X2: Connection to the Logic Unit (LE)
Flange socket with male insert (15-pin)
Pin No.
Signal
1 - 6
not assiged
7
video (P0)
8
not assigned
9
V SYNC
10
not assigned
11
0V signal
12 - 13
not assigned
14
H SYNC
15
clock
housing
external shield = housing