Plc: program memory erased, 1 machine parameter input – HEIDENHAIN TNC 306 Service Manual User Manual

Page 67

Advertising
background image

SERVICE MANUAL TNC 306/360

Page 60

HEIDENHAIN Service

15.1.1 Machine Parameter Input

OPERATION PARAMETERS ERASED

If this error message is displayed load the machine parameters as follows:

Press key

Function

CE

Clear

OPERATION PARAMETERS ERASED

CE

Clear

PLC: PROGRAM MEMORY ERASED

MOD

Configure the interface as described in section 14.2.

END

EXT

Prepare TNC for data input

Enter the program number under which the machine parameters
are stored.

ENT

Start data transfer

When the data transfer is finished, the following dialog

EXTERNAL DATA INPUT

1) is cleared.

END

Exit the machine parameter mode.

CE

Clear

POWER INTERRUPTED

1) If the error message

ENTRY VALUE INCORRECT

is generated during data input, this can be due to the following reasons:

- The TNC requires more machine parameters than are stored on the external data

medium (e.g. after a software exchange).

- At least one machine parameter has a non-permissible value.

- Press

ENT

to continue data transfer and enter the missing or incorrect parameter

values manually after the transfer.
Contact your machine tool manufacturer regarding these machine parameters.

Advertising