11 preassigned q parameters, Values from the plc: q100 to q107, Wmat block: qs100 – HEIDENHAIN iTNC 530 (340 49x-03) User Manual
Page 612: Active tool radius: q108

612
11 Programming: Q Parameters
1
1
.1
1 Pr
eassigned Q
P
ar
amet
ers
11.11 Preassigned Q Parameters
The Q parameters Q100 to Q199 are assigned values by the TNC.
These values include:
Values from the PLC
Tool and spindle data
Data on operating status
Results of measurements from touch probe cycles etc.
Values from the PLC: Q100 to Q107
The TNC uses the parameters Q100 to Q107 to transfer values from
the PLC to an NC program.
WMAT block: QS100
The TNC saves the material defined in the WMAT block in parameter
QS100.
Active tool radius: Q108
The active value of the tool radius is assigned to Q108. Q108 is
calculated from:
Tool radius R (Tool table or TOOL DEF block)
Delta value DR from the tool table
Delta value DR from the TOOL CALL block
Do not use preassigned Q parameters (or QS parameters)
between Q100 and Q199 (QS100 and QS199) as calculation
parameters in NC programs. Otherwise you might receive
undesired results.