background image

Setup & Operation 5. Motion Range

62

G3 Rev.1

Multiple Mounting : Left-Curved Arm


Center of Joint#3

Maximum space

Motion range

Area limited

by mechanical stop

Base mounting face

a b c d e f g h j k m

G3-351SM-L 3.3°

160°

2.8°

103.3 125.6

G3-351CM-L

130°

105° 5°

150°

12.8°

120°

125.6 140.5

183.0 191.6

n p q r s t x y z

G3-351SM-L 280.8
G3-351CM-L

220 350 271.4

277.2

186.9 205.2 162.8° 123.8° 3.8°

u v w

G3-351SM-L

150 9.6 6.7

G3-351CM-L

120 4.1 10.7

(°: degree)