Failure, Yield output, No communication – SMA Sunny Boy Control User Manual

Page 137: For 24h

Advertising
background image


Sunny Boy Control

SMA Technologie AG

User Manual

SUNBC

-

14

:

NE0206

133

Energy Yield Error: “Yield output xx %”

[ FAILURE ]

[03: WR700-07 ]

Device ID: device model

Yield output…

………………48%

Minimum yield expected compared with the daily system average

Fig. 9.5: Example of energy yield error

The device’s energy yield was below the tolerance.

•

Device defective or incorrectly installed.

•

“Energy” tolerance setting is too low (refer to section 6.2.4).

24 Hour Offline Error: “no communication for 24h”

[ FAILURE ]

[03: WR700-07 ]

Device ID: device model

no communication

for 24h

Device could not be reached for a whole day.

Fig. 9.6: Example of offline error

The device has been out of touch for a whole day. Data processing takes place at
00:00 (midnight).

Causes:

•

Device is defective or incorrectly installed.

•

Communication is interrupted.

•

Search for the cause using the function “Diagnostics…Communication”
(refer to section 5.2).