9.2.1 Transmission Failures

Causes:

•

Transmission signal strongly dampened

−

Transmission line too long

−

Adverse cable layout

•

Signal damping caused by other electrical devices

−

Anti-interference capacitors such as those found in fluorescent lamps

•

Insufficient phase coupling

−

Sunny Boy Control and Sunny Boy inverters connected to different phases

−

Interference from external communication signals

−

Baby monitors etc. in the neighborhood

•

Interference from your own communication signals

−

Baby monitor

−

Intercom etc.

All of the above sources affect the quality of the transmission, but they do not neces-
sarily prevent Powerline communication. While in one household Powerline commu-
nication may be possible without a problem over several phases and a 90 m / 300 ft
line, in another one, there may be strong interference over a single phase and a
30 m / 100 ft line.

The following sections explain the most common causes for Powerline communication
failures and give possible countermeasures aimed at suppressing interference. In case
of a transmission failure between the Sunny Boy Control and a connected device,
refer to these sections first, and then try to find the source of the failure by carrying
out the steps described in section 9.2.2.