7 Troubleshooting

24

YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual

Preventing Electrical Signal Interference

Take the following steps to prevent erroneous operation caused by electrical signal

interference:

• Use shielded wire for the signal lines.

• Limit the length of wiring under 50 m (164 ft.).

• Separate the control wiring to the option, main circuit wiring, and power lines.

Interface Circuit

Figure 11

Figure 11 Output Interface Circuit

Digital Operator Display

Fault Name

oFC02

Option Fault (CN5-C)
Two of the same options are connected simultaneously.

Cause

Possible Solution

Same type of option connected to unit ports
CN5-A, CN5-B, and CN5-C.

Use only compatible options.

+

V1, V2

AC

Signal

processor

AO