5. Connect the grounding lead wire from the DI-16H2 card to terminal 12 on the Control Board.

6. Wiring. See Figure 3 and Tables 2 & 3 for Digital Reference Card (DI-16H2) connections. Connect digital
input signals to terminal blocks TC1 and TC2. Route wires from the GPD 515/G5 and connect to the peripheral
device(s). Refer to "Electrical Installation" in the GPD 515/G5 technical manual for further information on use of
shielded cable.

Table 1. Specifications of DI-16H2 Card

Parameter

Value

Input Data Signal

Binary 16 Bit/BCD 4 digits

Selected by swtich S1

Binary 12 bits/BCD 3 digits

SIGN and SET Signal Voltage

+24V

Control voltage input (from GPD 515/G5): 24V (isolated)

Figure 1. Digital Reference Card DI-16H2

Connector (on back side of card)
to Control Board (2CN)

2 mounting
holes
(0.16 in. dia.)

Terminal
block TC2

Terminal
block TC1

Switch S1
(for selecting input data configuration)

Terminal TC3
(for connecting
shielded
sheath)

Grounding lead wire (connects to
terminal 12 on Control Board)

Table 2. Applicable Wire Sizes For TC1 and TC2

Wire Type

mm

2

AWG

Current (Amps)

VAC

Thin twisted wire

1

16

12

125

Solid wire

1.5

16

12

125

UL

——

22-16

10

300

CSA

——

28-16

10

300

CSA

——

28-16

10

150