Table 1. Specifications

Parameter

Symbol

Min.

Typ.

Max.

Units

Test Conditions

High Level Voltage Input

V

IH

12.5

24.0

V

R

L

> 8.9 K

Low Level Voltage Input

V

IL

0

12.0

V

R

L

< 8.8 K

Logic Low Current

6.4

10

mA

Control voltage input (from drive): 24V (isolated)

Table 2. Terminal Functions of DI-08

Function

Terminal

Binary Input

BCD Input

Notes

TC1

2

0

1

TC2

2

1

2

— "On" when closed (shorted to 0V at TC11);

TC3

2

2

4

x 10

0

"Off" when open.

TC4

2

3

8

TC5

2

4

1

— Binary / BCD selection and input unit is set by

TC6

2

5

2

GPD 515 parameter F3-01 (see Table 3) or

TC7

2

6

4

x 10

1

GPD 503 constant Sn-26 (see Table 4).

TC8

2

7

8

TC9

Sign (polarity) signal

— Terminal screws are metric size M3.

TC10

Push-to-load

TC11

Signal common (0V)

5. Wiring. See Figure 3 for Digital Speed Reference (DI-08) connections. Connect digital input signals to
terminals TC1-TC10 (+) and TC11 (-). See Table 2 for terminal functions.

CAUTION

KEEP DIGITAL SIGNAL (I.E. CONTROL CIRCUIT) WIRING
SEPARATE FROM MAIN CIRCUIT INPUT/OUTPUT WIRING.

CAUTION

TO PREVENT ERRONEOUS OPERATION CAUSED BY NOISE
INTERFERENCE, USE SHEILDED CABLE FOR DIGITAL SIGNAL
WIRING, AND LIMIT DISTANCE TO 10M (33 FEET) OR LESS.

IMPORTANT

The DI-08 input circuits can receive output of relay contacts or transistor (open
collector).

– Use relays with highly reliable contacts (for very small current) with a

capacity of 30VDC or more and rated current of 100mA or higher.

– Use transistor (open collector) with rated voltage of 35VDC or more and

rated current of 30mA or higher.