Yaskawa DS388 User Manual

Page 5

Advertising
background image

Refer to Sheet 1 for latest change.

DWG. NO. 02Y00025-0294

SHEET NO. 5 OF 6

R E L . 0 1 / 2 9 / 9 1

( m - df )

Table 4. GPD 503 Digital Reference Selection

Sn-26

Setting Unit

Setting Range

Set Value

0000

BCD

1%

0 — 159 %

0001

BCD

0.1%

0 — 15.9 %

0010

BCD

0.01%

0 — 1.59 %

0011

BCD

1Hz

0 — 159 Hz

0100

BCD

0.1Hz

0 — 15.9 Hz

0101

BCD

0.01Hz

0 — 1.59 Hz

0111

Binary

255/100%

0 — Max. Output Freq

(1)

1000

Binary

255/100%

0 — Max. Output Freq

(2)

(1)

Display is in % of maximum frequency (Sn-02).

(2)

Display is the decimal equivalent of the binary number.

IMPORTANT

The drive needs to be programmed to use the digital speed reference. This can
be done in one of two ways:

Drive Always Uses Digital Speed Reference:

GPD 515:

Program b1-01 = " 3 " (Option PCB)

GPD 503:

Program Sn-04 = XXX0 and Sn-08 = XXX0

Select Digital Speed Reference or Keypad/Terminal with a Multi-function
Input:

GPD 515:

Program b1-01 = " 0 ", " 1 ", or " 2 " (depending on

required refenrece source)

Program H1-03 (or other input) = " 2 " (Option / Inv Sel)
Close Terminals 5 to 11 on the main PCB to select digital

reference

GPD 503:

Program Sn-04 = XXX0 and Sn-08 = XXX0
Program Sn-15 (or other input) = " 2 " (Option / 503)
Open Terminal 5 to 11 on the main PCB to select digital

reference

Table 3. GPD 515 Digital Reference Selection

F3-01

Setting Unit

Setting Range

Set Value

0

BCD

1%

0 — 159 %

1

BCD

0.1%

0 — 15.9 %

2

BCD

0.01%

0 — 1.59 %

3

BCD

1Hz

0 — 159 Hz

4

BCD

0.1Hz

0 — 15.9 Hz

5 & 6

BCD

0.01Hz

0 — 1.59 Hz

7

Binary

255/100%

0 — Max. Output Freq

Advertising