Yaskawa GPD515-XXXX-CS004 User Manual

Page 2

Advertising
background image

Added Parameters:

This software does not add any new parameters to the drive.

Changed Parameters:

Refer to Appendix 1 ot the GPD 515 Technical Manual, TM 4515. The following changes result from
the installation of this software in the drive.

Parameter

Function Name

Changed

Standard

1000 Hz

Software

Software

A1-02

Control Method Selection

Max. Value

3

0

Factory Setting

2

0

b3-03

Speed Search Deceleration

Min. Value

0.0

1.0

Time

b6-01

Dwell Frequency at Start

Max. Value

400.0

1000.0

b6-03

Dwell Frequency at Stop

Max. Value

400.0

1000.0

b8-02

Energy Saving Frequency

Max. Value

400.0

1000.0

C6-01

Carrier Frequency Upper Limit

Max. Value

15.0

(1)

10.0

(1)

C6-02

Carrier Frequency Lower Limit

Max. Value

15.0

(1)

10.0

(1)

d1-01 thru

Frequency References

Max. Value

400.0

1000.0

d1-08

Increment

0.01

0.1

d1-09

Jog Frequency Reference

Max. Value

400.0

1000.0

Increment

0.01

0.1

Factory Setting

6.00

60.0

d2-02

Reference Lower Limit

Max. Value

100.0

109.0

d3-01 thru

Critical Frequency Rejection

Max. Value

400.0

1000.0

d3-03

E1-04

Max Frequency

Max. Value

400.0

1000.0

E1-06

Base Frequency

Max. Value

400.0

1000.0

E1-07

Mid Frequency A

Max. Value

400.0

1000.0

E1-09

Min Frequency

Max. Value

400.0

1000.0

E1-11

Mid Frequency B

Max. Value

400.0

1000.0

H1-01 thru

Multi-Function Input Terminal

Max. Value

77

66

H1-06

Selection

L2-04

Power Loss V/F Ramp Time

Max. Value

2.0

5.0

L4-01

Speed Coincidence Level

Max. Value

400.0

1000.0

L4-03

Speed Coincidence Level + –

Max. Value

400.0

1000

Min. Value

–400.0

–1000

Increment

0.1

1

(1)

Setting will differ depending on drive capacity

Doc. No. 02Y00025-0420