Analog output option card ao-08 or ao-12, Ao-08 or ao-12 card – Yaskawa AO-08 User Manual

Page 2

Advertising
background image

Yaskawa Electric America, Inc. – www.drives.com

IG.AFD.51, Page 2 of 4

Date: 07/01/04, Rev: 04-07

Analog Output Option Card

AO-08 or AO-12

F7, G7,

GPD515/G5,

G5HHP

L1

L2

L3

T1
T2
T3

E

TD1

AO-08 or AO-12 Card

33000 PF

0V

0V

TYPICAL CIRCUIT
BOTH CHANNELS

0V

D/A
CONVERTER

200

I M

MOTOR

MCCB

SHIELD

3CN

3CN

(GREEN)

FM

AM

+




+

-




-

10K

10K

MTR
CAL

MTR
CAL

TD3

TD2

Grounding
Terminal:
F7, G7 = TB3
G5 = 12

E

Figure 2. AO-08 / AO-12 Interconnection Diagram


Table 2. Terminal Functions of the AO-08 and AO-12

Signal Level

(1)

F7/G7

GPD515/G5

Terminal

Functions

AO-08

AO-12

AO-08

AO-12

TD1

Analog signal

output channel 1

TD2

Analog signal

output channel 2

0-10VDC

0-10VDC

or

+/-10VDC

0-10VDC

0-10VDC

or

+/-10VDC

TD3 Output

Common

0V

(1) F7/G7: Selectable by setting of drive parameters F4-07 (TD1) and F4-08 (TD2).

GPD515/G5: Selectable by setting of drive parameter H4-07.

Table 3. Adjustment of Output Signal Scaling

Drive

Terminal

Gain Parameter

(1)

Setting

Range

Increment

Factory

Setting

Remarks

TD1 F4-02

0.0-

1000.0%

0.1% 100%

F7/G7

TD2 F4-04

0.0-

1000.0%

0.1% 50%

10VDC / 100 %

(2)

TD1 F4-02

0.00 to

2.50

0.01 1.00

GPD

515/G5

TD2 F4-04

0.00 to

2.50

0.01 0.50

10VDC / 1.00

(2)

(1) A gain of 0.5 will set 5VDC = 100%; a gain of 2.0 will set 10VDC = 50%.
(2) Maximum output signal level is +11VDC.

Advertising