Encoder feedback option card pg-x2 – Yaskawa PG-X2 User Manual

Page 8

Advertising
background image

Yaskawa Electric America, Inc. – www.drives.com

IG.AFD.60, Page 8 of 8

Date: 07/01/04, Rev:04-07

Encoder Feedback Option Card

PG-X2

Table 3. GPD 515/G5, F7, and G7 Encoder Feedback Parameter List

Control

Method (2)

Digital Operator

Func

tion Group

Digital Operator

Disp

lay

Parameter Number

Parameter Name

Se

tting Ra

nge

Fa

c

tory

Se

tting

Cha

nge

During

Op

eratio

n

(1)

Data Selectio

n

V/f w/ PG

F

eed

b

ack

Flux

Ve

c

tor

ASR P Gain 1

C5-01

ASR

Proportional

Gain 1

0 to

300.00

0.00 O

O

O

ASR I Time 1

C5-02

ASR Integral

Time 1

0 to

10.000s

0.00s O

O

O

ASR P Time 2

C5-03

ASR

Proportional

Gain 2

0 to

300.00

0.00 O

O

O

ASR I Time 2

C5-04

ASR Integral

Time 2

0 to

10.000s

0.00s O

O

O

ASR Limit

C5-05

ASR Limit

0.0 to

20%

0.0% X

O

X

ASR Delay

Time

C5-06

ASR Primary

Delay Time

0.000 to

0.500s

0.000s X

X

O

ASR Gain SW

Freq

C5-07

ASR Switching

Frequency

0.0 to

400.00Hz

0.0Hz X

X

O

ASR

Tuning

ASR Integral

Limit

C5-08

ASR Integral

Limit

0 to

400%

400% X

X

O

(1) O = Yes, X = No.
(2) O = Available, X = Hidden. The PG-X2 is not applicable for A1-02 = 0 (V/f Control) or 2 (Open Loop Vector).