Digital Operator Remote Mount Option Kits

UUX000458, UUX000459

Yaskawa Electric America, Inc – www.drives.com

IG.AFD.72, Page 2 of 4

Date: 6/14/07, Rev: 07-06


Chemical Resistance: The materials used in this kit were chosen specifically for resistance to harsh environments. This kit
provides short-term protection from many chemicals, including the list below. For additional information, please contact the factory.

• Toluene
• Isopropyl Alcohol

• Cyclohexanone
• Ethyl Acetate
• Xylene
• 40% NaOH
• Concentrated HCl

• Gasoline
• Butyl Cellosolve


Kit Installation:

1. Turn off power to the drive by completely removing power to the enclosure. Wait 5 minutes for capacitor discharge.
2. Unpack and verify the contents of the Digital Operator Remote Mount Kit.
3. Create the cutout at the desired location on end-use enclosure as shown below. Please use the 1:1 cutout template

(drawing UDM00201) included in this kit. Note that 3.0” clearance is required behind the operator kit to allow for cable
routing. All dimensions +/- 0.03”.

Figure 1a – Cutout Drawing Figure 1b – Side Assembly View Showing Recommended

Bending

Radius

(Depth)

Advertising