Yaskawa UUX000458 User Manual
Page 2
 
Digital Operator Remote Mount Option Kits
UUX000458, UUX000459
Yaskawa Electric America, Inc – www.drives.com
IG.AFD.72, Page 2 of 4
Date: 6/14/07, Rev: 07-06
 
Chemical Resistance: The materials used in this kit were chosen specifically for resistance to harsh environments. This kit 
provides short-term protection from many chemicals, including the list below. For additional information, please contact the factory. 
 
• Toluene 
• Isopropyl Alcohol 
• Cyclohexanone 
• Ethyl Acetate 
• Xylene 
• 40% NaOH 
• Concentrated HCl 
• Gasoline 
• Butyl Cellosolve 
 
Kit Installation: 
1. Turn off power to the drive by completely removing power to the enclosure. Wait 5 minutes for capacitor discharge. 
2. Unpack and verify the contents of the Digital Operator Remote Mount Kit. 
3. Create the cutout at the desired location on end-use enclosure as shown below. Please use the 1:1 cutout template 
(drawing UDM00201) included in this kit. Note that 3.0” clearance is required behind the operator kit to allow for cable 
routing. All dimensions +/- 0.03”. 
 Figure 1a – Cutout Drawing Figure 1b – Side Assembly View Showing Recommended 
 
Bending
Radius
(Depth)