Yaskawa Remote Serial Communication Controller LAN Node PCB for use with Microtrac DSD LAN User Manual

Page 17

Advertising
background image

17

RD 790-30

002H 00CH 03FH 080H 000H 000H 00AH

| |

|

|

Channel #2————————————— 002H |

|

|

Subchannel #12——————————————00CH

|

|

Value, floating pt value of 1.0—————————————03F800000H

|

Checksum ——————————————————————————————— 00AH

EXAMPLE 2. External device requests that a new modifiable parameter be

displayed, and then modifies the value.

EX2.1. External device sends a Display Abort message to drive #20.
The data sent over the serial port from the external device to the

RSC is as follows (in the given order):

001H 0FEH 004H 014H 021H

|

|

|

|

Start of message sequence (SOH, NOT SOH)——— 001H 0FEH |

|

|

Length, 4 bytes——————————————————————— 004H

|

|

Drive #20————————————————————————————— 014H

|

Message Type 021H, Display Abort————————————————————021H

00AH 043H

|

|

RDU #10——————————————————————————————00AH |
Checksum————————————————————————————————043H

EX2.2. External device sends a Display Node Request to drive #1.
The data sent over the serial port from the external device to the

RSC is as follows (in the given order):

001H 0FEH 007H 001H 020H

|

|

|

|

Start of message sequence (SOH, NOT SOH)——— 001H 0FEH |

|

|

Length, 7 bytes————————————————————————007H

|

|

Drive #1——————————————————————————————001H

|

Message Type 020H, Display Node Request————————————————020H

065H 000H 06EH 00AH 005H

|

|

|

|

Channel #101—————————————————— 065H

|

|

|

Subchannel #110———————————————————— 0006EH

|

|

RDU #10——————————————————————————————00AH |
Checksum————————————————————————————————005H