Yaskawa Remote Serial Communication Controller LAN Node PCB for use with Microtrac DSD LAN User Manual
Page 18

18
RD 790-30
EX2.3. Drive #1 responds with Display Variable ASCII Response message. The data sent over
the serial port from the RSC to the external device is as follows (in the given order):
001H 0FEH 030H 001H 023H
|
|
|
|
Start of message sequence (SOH, NOT SOH)——— 001H 0FEH |
|
|
Length, 48 bytes———————————————————————030H
|
|
Drive #1——————————————————————————————001H
|
Message Type 023H, Display Variable ASCII Response———————————023H
00AH
|
RDU #10———————————————————————————————— 00AH
020H 020H 020H 04CH 049H 04EH 045H 020H
053H 050H 045H 045H 044H 020H 020H 020H
|
Bottom Line ASCII Text——————————— “ LINE SPEED ”
043H 04FH 041H 054H 045H 052H 020H 020H
020H 020H 020H 020H 020H 046H 050H 04DH
|
Top Line ASCII Text—————————————“COATER FPM”
044H 07AH 000H 000H
|
Upper Limit, floating pt value of 1000 ——————————— 0447A0000H
000H 000H 000H 000H
|
Lower Limit, floating pt value of 0 ————————————— 000000000H
000H 000H 000H 000H
|
Initial Value, floating pt value of 0 ————————————— 000000000H
016H
|
Checksum————————————————————————————————016H