Yaskawa Remote Serial Communication Controller LAN Node PCB for use with Microtrac DSD LAN User Manual
Page 21

21
RD 790-30
020H 000H 008H 001H
|
Logic Mask, configuring subchannels 0, 11, and 29————— 020000801H
000H 000H 000H 000H
|
Sink/Source Mask, all sink—————————————————000000000H
05AH
|
Checksum ——————————————————————————————— 05AH
EX3.2. External device keeps drive #15 updated by sending Logic Update messages when any
of the configured logic inputs change state and at approximately 4 second intervals. The data
sent over the serial port from the external device to the RSC is as follows (in the given order):
001H 0FEH 008H 00FH 031H
|
|
|
|
Start of message sequence (SOH, NOT SOH) ——— 001H 0FEH |
|
|
Length, 8 bytes ——————————————————————— 008H
|
|
Drive #15————————————————————————————— 00FH
|
Message Type 031H, Logic Update——————————————————---—— 031H
004H
|
Channel #4——————————————————————————————— 004H
000H 000H 008H 000H
|
Value, subchannel 0 and 29 at logic 0 and
|
subchannel 11 at logic 1 ——————-------——————— 000000800H
054H
|
Checksum ——————————————————————————————— 054H