Station-number setting – Yaskawa VS-606V7 User Manual

Page 13

Advertising
background image

3 Component Names and Settings

13

„

Station-number Setting

A station number is set by both the S1-3 DIP switch and the S2 rotary switch. Station num-
bers from 21 to 3E are valid. Although 20 or 3F can be set as a station number, do not use
these settings because they will be faulty.

S1-3:Set the 10’s digit of the station number.

OFF = 2 (2X)
ON = 3 (3X)

S2: Set the 1’s digit of the station number.

0 = 0 (X0)
1 = 1 (X1)

x

 

x

x

 

x

F = F (XF)

Switch Setting and Station Number

SI-3

S2

Station

Number

S1-3

S2

Station

Number

OFF

0

Fault

ON

0

30

OFF

1

21

ON

1

31

OFF

2

22

ON

2

32

OFF

3

23

ON

3

33

OFF

4

24

ON

4

34

OFF

5

25

ON

5

35

OFF

6

26

ON

6

36

OFF

7

27

ON

7

37

OFF

8

28

ON

8

38

OFF

9

29

ON

9

39

OFF

A

2A

ON

A

3A

OFF

B

2B

ON

B

3B

OFF

C

2C

ON

C

3C

OFF

D

2D

ON

D

3D

OFF

E

2E

ON

E

3E

OFF

F

2F

ON

F

Fault