21 (1) related parameters – Yaskawa Sigma II Series SGMVH User Manual
Page 281

9.5 Analog Monitor
9
Adjustments
9-21
(1) Related Parameters
The following signals can be monitored.
(a) Pn003: Function Selections
* When using speed control or torque control, the position error monitor signal is not specified.
The analog monitor output voltage is ±8 V (maximum). The output will be limited to ±8 V even if this value is exceeded
in the above calculations.
Parameter
Function
Monitor 1
Monitor 2
Monitor Signal
Observation Gain
Remarks
Pn003
n.0
n.0
Motor speed
1 V / 1000 min
-1
Factory setting for Monitor 1
n.1
n.1
Speed reference
1 V / 1000 min
-1
−
n.2
n.2
Internal torque reference
1 V / 100% rated torque
Factory setting for Monitor 2
n.3
n.3
Position error
∗
0.05 V / 1 reference unit
−
n.4
n.4
Position error
∗
0.05 V / 100 reference units
−
n.5
n.5
Position reference speed
(converted to motor speed)
1 V / 1000 min
-1
−
n.6
n.6
Motor speed
1 V / 250 min
-1
−
n.7
n.7
Motor speed
1 V / 125 min
-1
−
n.8
n.8
Reserved. Do not set.
−
−
n.9
n.9
−
n.A
n.A
−
n.B
n.B
−
n.C
n.C
−
n.D
n.D
−
n.E
n.E
−
n.F
n.F
−
INFO