4 technical data, 1 electrical data, Technical data – KACO Powador-gridsave User Manual

Page 11: Electrical data, 4technical data

Advertising
background image

Technical Data

Operating instructions Powador-gridsave_EN

Page 11

4

Technical Data

4.1

Electrical data

Connection box

Home power grid

Input voltage

230V / 400V; 50Hz / 60Hz , 3-phase (3, N, PE)

Grid configuration

TN-C, TN-S, TT

Grid monitoring

Powador-protect (as per VDE-AR-N 4105)

Grid isolation

Double insulated, 3 or 4 pin

Rated operating current [A]

75

Rated switching current AC-1 [A]

100

Rated switching current AC-3 [A]

50 (22 kW at 400 V)

Connection cross-section [mm²]

max. 25

PV input

Input voltage [V]

300 to 800

Input current [A]

30 / String

Strings

2

Isolation

Yes, rotary switch

Inverter type

6400

8000

Input levels

Max. recommended PV generator power

[W]

7700

9600

Rated power / peak power [VA]

6400 / 7000

8000 / 9000

DC MPP range from [V] to [V]

360... 590

Open circuit voltage [V]

800

Input current [A]

19.0

24.0

cos phi

0.8 inductive … 0.8 capacitive

Polarity safeguard

Short-circuit diode

Feed-in phases

1

Capable of stand-alone operation

Yes

Efficiency [%]

96.6

Output levels

Output voltage

230V, 50Hz / 60Hz , 1-phase

Rated current [A]

27.8

35

Connection cross-section [mm²]

max. 6

Monitoring / Isolation

Circuit breaker, residual current circuit breaker (RCD)