29

Release Number - NV Address = 0x78
This register indicates the firmware release number for the module. Figure
38 translates the r
elease numbers to firmware versions. Figure 39 shows
examples of the command.

Release Number to Version Number

Release Number

Module Type

Version Number

0

DTS

1.1.0

1

EUR

1.2.6

2

DTS

1.2.6

3

EUR

1.3.1 (current)

4

DTS

1.3.0 (current)

5

DTS-FCC

1.3.0 (current)

8

DTS-FCC

1.3.0 (current)

18

DTSB

1.3.0 (current)

Figure 38: Release Number Command and Response

Figure 39: Release Number Command and Response

Release Number

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

ADDR

0x06

ADDR

REL#

Typical Applications

Figure 40 shows a circuit using the DTS Series transceiver.

The transceiver UART is connected to a microcontroller UART for
communication of configuration data and data to be sent over the air.
There is no need for buffering or other circuitry between the transceiver and
microcontroller provided that both are operating on the same voltage.

RESET

GND

1

NC

2

NC

3

CMD

4

RXD

5

TXD

6

CTS

7

NC

8

NC

9

C2D

10

11

GND

12

ANT

13

GND

14

GND

15

GND

16

GND

17

GND

18

VCC

19

GND

VCC

ANTENNA

GND

GND

GND

GND

GND

GND

GND

RXD

TXD

GPIO

GPIO

µ

Figure 40: DTS Series Transceiver Basic Application Circuit