Description, Features, Applications – Linx Technologies TXM-xxx-ES User Manual

Page 3: Data guide, Es series rf transmitter

Advertising
background image

– –

1

Description

Housed in a tiny SMD package, the ES Series offers
an unmatched combination of features, performance
and cost-effectiveness. The transmitter utilizes an
advanced FM / FSK-based synthesized architecture
to provide superior performance and noise immunity
when compared to AM / OOK solutions. A 56kbps
maximum data rate and wide-range analog capability
make the ES Series equally at home with digital data
or analog sources. It provides a host of useful features including power
down, output power adjustment, low voltage detect and a microprocessor
clock source. The ES operates in the 900MHz (US) or 869MHz (EU) band,
which in North America allows a wide variety of applications, including data
links, audio links, home and industrial automation, security, remote control /
command and monitoring. Like all Linx modules, the ES Series requires no
tuning or external RF components except an antenna.

Features

• Ultra-compact SMD package
• FM / FSK modulation
• Wide bandwidth (20Hz to 28kHz)
• Very low current consumption
• Data rates to 56,000bps
• User power-down input
• Low-voltage detect output
• Microprocessor clock output

• No production tuning
• No external RF components

needed

• Precision-frequency synthesized

architecture

• Direct interface to analog and

digital sources

• Excellent cost / performance ratio

Applications

• Wireless Data Transfer
• Wireless Analog / Audio
• Home / Industrial Automation
• Keyless Entry
• Remote Control
• Fire / Security Alarms

• Wireless Networks
• Remote Status Sensing /

Telemetry

• Long-Range RFID
• RS-232 / 485 Data Links
• Voice / Music Links / Intercom

ES Series RF Transmitter

Data Guide

Figure 1: Package Dimensions

Revised 3/18/2015

24

Common Antenna Styles

26

Regulatory Considerations

0.125"

0.630"

0.510"

LOT ST9xxx

TXM-916-ES

Warning:

This product incorporates numerous static-sensitive

components. Always wear an ESD wrist strap and observe proper ESD
handling procedures when working with this device. Failure to observe
this precaution may result in module damage or failure.