Arrow keys, Function keys – Epson TP1 User Manual
Page 31

Functions & Installation 5. Operation Panel (Key Description)
TP1 Rev.5
21
Arrow Keys
Mode switches by turning ON/OFF the “F5-8” lamp.
Press the <F1-4 / F5-8> key to turn ON/OFF the “F5-8” lamp.
F5-8 Mode
Key
Function
↑
+1 the value
Move the cursor up
↓
−1 the value
Move the cursor down
←
Move the cursor to the left
OFF Normal
mode
→
Move the cursor to the right
<<
+10 the value
Move to previous page
>>
−10 the value
Move to next page
<<
High speed cursor motion to the left
ON Scroll
mode
>>
High speed cursor motion to the right
Function Keys
Press the <F5-8> key to turn ON/OFF the “F5-8” lamp. The display changes.
Example : Jog&Teach Screen
<F1>
<F2>
<F3>
<F4>
“F5-8” OFF
“F5-8” ON
<F5>
<F6>
<F7>
<F8>
Example : Press the <F3> key to display the Motion screen.
When a function key is not assigned to a screen, the key is invalid. Example : <F7>
NOTE