[Before Adjustment]
- Input a 100% of black raster signal.

[R/G/B-CONTRAST ADJUSTMENT]
1

Loosen a screw

A

(Fig.1-1/1-2) on the polarized glass mounting

base which you intend to adjust.

2

Turn the polarized glass mounting base as shown in Fig.1-1 to
obtain the darkest brightness on the screen.

3

Tighten the screw

A

to fix the polarized glass mounting base.

Repeat steps 1 to 3 for remaining polarized glasses.

B-Polarized Glass
Mounting Base

R-Polarized Glass
Mounting Base

G-Polarized Glass
Mounting Base

A

A

A

Slot B

Fig.1-

2

Fig.1-

1

Polarized

glass

mounting base

Optical Adjustments

Main Board

A

Contrast adjustment

Before taking optical adjustments below, remove the Cabinet Top and Main Board following to the “Mechanical
Disassemblies”
Adjustments require a 2.0mm hex wrench and a slot screwdriver. When you adjust Condenser lens, Condenser
lens-out or Relay lens adjustment, you need to disconnect some connectors and FPC cables of LCD panels on the
main board.
Note: Do not disconnect connectors K8N, K8P, K8H, K8R and K8S on the main board, because the projector can

not turn on due to operate the power failure protection.