Eiki LC-NB3E User Manual

Page 27

Advertising
background image

-27-

Electrical Adjustments

1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.

[R-SIGNAL CENTER ADJUSTMENT]
4. Connect a digital voltmeter to test point “

TP25R1

” (+)

and chassis ground (-).

5. Select group no. “

3

”, item no. “

0

” and change data

value to adjust the voltage to be 7.30 ±0.05V.

[G-SIGNAL CENTER ADJUSTMENT]
6. Connect a digital voltmeter to test point “

TP25G1

” (+)

and chassis ground (-).

7. Select group no. “

3

”, item no. “

1

” and change data

value to adjust the voltage to be 7.30 ±0.05V.

[B-SIGNAL CENTER ADJUSTMENT]
8. Connect a digital voltmeter to test point “

TP25B1

” (+)

and chassis ground (-).

9. Select group no. “

3

”, item no. “

2

” and change data

value to adjust the voltage to be 7.30 ±0.05V.

1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Connect an oscilloscope to test point “TP3551” (+)

and chassis ground (-).

4. Enter the service mode, select group no. “

3

”, item no.

7

” and change data value to adjust amplitude “a” to

be 4.8 ±0.1V.

(a)

Signal Center adjustment

NRS adjustment

1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.

[R-BLACK ADJUSTMENT]
4. Connect an oscilloscope to test point “

TP25R1

” (+)

and chassis ground (-).

5. Select group no. “

3

”, item no. “

3

” and change data

value to adjust amplitude “a” to be 10.0 ±0.1V.

[R-BLACK ADJUSTMENT-]
6. Connect an oscilloscope to test point “

TP25G1

” (+)

and chassis ground (-).

7. Select group no. “

3

”, item no. “

4

” and change data

value to adjust amplitude “a” to be 10.0 ±0.1V.

[R-BLACK ADJUSTMENT-]
8. Connect an oscilloscope to test point “

TP25B1

” (+)

and chassis ground (-).

9. Select group no. “

3

”, item no. “

5

” and change data

value to adjust amplitude “a” to be 10.0 ±0.1V.

(a)

black level

black level

Black Level adjustment

Advertising