Data Format Specifications

This command is executed in the form of 1-command/1 packet. The next command is not
accepted until the previous processing is completed.

• The communication command always starts with STX (Start of Text) , and ends with ETX

(End of Text) .

• If the communication format or command name is wrong, NAK (Negative

Acknowledgement) will be sent from this product as a result of failing to receive correctly.

• When the communication format is correctly received, this product sends ACK (Normal

Acknowledgement).

Transmission Command (PC Visual Presenter)

Each operation command is executed in ASCII code, and transmitted in a set of 7 bytes as
follows:

Response data format (Visual Presenter PC)

All response data is transmitted as ASCII code, and it coverds parameter of the table of
operation command.
• Status 0

• Status 2

S

T

X

E

T

X

Command

(PC)

(Visual Presenter)

→ ACK

Data

Parameter

S

T

X

P

osi

/

N

ega

C

olor

/ B&W

P

ointer

display

E

lectronic

enlargement

L

ocal

lock

o ut

E

T

X

RGB

output

selection

L

ighting

selection

P

ause

γ

adjustment

32H

Video

output

selection

S

T

X

Image

rotation

Aperture White

balance

Contrast

30H

(Normal)

31H

(Adjustment)

E

T

X

Advertising