Maintenance instructions, Mt gb – Florabest FTS 1100 A1 User Manual
Page 37
 
37
MT
GB
the unused pump outlet is fully 
closed.
• Avoid that the pump runs dry.
• Check that the electrical connec-
tion is 230V ~50Hz
• Check the proper status of the
electrical plug socket and make 
sure that the plug socket is suf-
ficiently fused (at least 6 A). In-
sert the pump plug into the plug 
socket and the pump is ready 
for operation.
• Make sure that moisture or wa-
ter never come in contact with 
the mains connection.
• There is a risk of electrocution.
Maintenance
Instructions
Clean and maintain your equipment regu-
larly. This will guarantee its performance 
and long durability.
Ask our service centre to carry out
any work that is not described in 
these instructions. Use only original 
parts. 
Pull out the power plug before every
maintenance operation. There is a 
risk of electrocution or of injury from 
moving parts.
General cleaning instructions
• In case of transport for utilization in differ-
ent locations, the pump must be cleaned 
with clear water after every use.
• In case of stationary installation, the func-
tion of the float switch is to be checked 
regularly (at the latest every three 
months).
• With a water jet, remove fluff and
fibrous particles which are possibly 
present in the pump casing
• Regularly remove sludge from the pit
base (at the latest every 3 months) and 
also clean the shaft walls
• Clean precipitation from the float
switch with clear water,
• In the case of a long period of non-use,
the pump must be thoroughly cleaned 
after the last use and before the new 
use, since difficulties in start-up can 
arise due to precipitation and residues.
Cleaning the Fan Wheel
In case of soiling or blockage of the impel-
ler, this can be cleaned via the pump out-
let (3) or by removing the floor plate (4):
C
1. Unscrew the bracket adapter
(10) from the pump outlet (3).
2.
Remove the 3 screws on the 
bottom of the pump casing (2) 
and take off the floor plate (4).
3.
Clean the fan wheel using 
clean water. 
4.
To re-assemble, reverse this 
order.
Any measures above and beyond these, 
particularly opening the equipment, are to 
be carried out by an electrician. 
In the case of repairs, always contact our 
service centre.
Storage
• Keep the equipment clean, dry and out
of the reach of children.
• Unscrew the bracket adapter (10) for
storage.