Connecting to the Network

Matrix DFE-Gold Series PoE Module 4H4285-49 Installation Guide 3-17

f.

Ensure that the twisted pair connection meets the dB loss and cable specifications 
outlined in the Cabling Guide. Refer to 

 “Related Documents” 

on page xvi for 

information on obtaining this document. 

If a link is not established and it is connected to a PD device, check the PoE Port 
Status to ensure that there is 48 Vdc power at the 4H4285‐49 RJ45 port. Refer to 

“Verifying PoE Port Status” 

on page 3‐17. If there is still a problem, contact 

Enterasys Networks. Refer to 

 “Getting Help” 

on page xviii for details.

4.

Repeat steps 1 through 3 above, until all connections have been made.

Verifying PoE Port Status

If a PD is connected to the 4H4285‐49 RJ45 port, ensure that there is power at the RJ45 port 
as follows:

1.

Press on the GROUP SELECT button for more than one second. The 4H4285‐49 will 
enter the PoE status mode, which will indicate a set of power status conditions 
relating to the PoE Port Status. 

2.

Now, every time you press the GROUP SELECT button for less than a second, the 
GROUP LED lights up in sequence, indicating which Group is selected. The PoE 
POWER STATUS for that group of segments is then indicated by the RX and TX LEDs 
for each segment. If there is power at the port, the RX LED is green and the TX LED is 
off. Otherwise, refer to 

Chapter 4

 for troubleshooting information.

Figure 3-8 Eight-Wire Straight-Through Cable RJ45 Pinouts, Connections
Between Switches and End-User Devices

1 RJ45 device port

3 RJ45-to-RJ45 straight-through cable

2 Other device port

TX1+

TX2+

RX4-

RX1-

TX4+

RX3-

TX3+

RX2-

2

1

3

6

4
5

7
8

TX2+

TX1+

RX3-

RX2-

TX3+

RX4-

TX4+

RX1-

2

1

3

6

4
5

7
8

В

А

Б