Start-up – Florabest FTP 400 B2 User Manual

Page 45

Advertising
background image

45

GB

Start-up

Assembly

To screw-on the adapter:

1. Screw the angle adapter (11)

and the adapter with the hose

connection (9) onto the pump

outlet (5).

Installing the float switch

2. Position the float switch cable (7)

in the float switch grid (8).

Connection of the pressure

line

The installation of the submersible water

pump is implemented either

- with fixed pipe or

- with flexible hose line

• If using a ½” hose, attach the

hose over the pump’s hose con-

nection (9) and fasten it with a

hose clamp if necessary.

• To use a ¾”, 1“ or 1½” hose, cut

off the connection above and at-

tach the hose over the correct con-

nection

(fixing with a hose clamp)

.

• To use a tap adaptor (G1“) to

connect external hose connec-

tion systems, cut off the two top

connections directly above the

G1“ tube thread.

Measurement of maximum output

data takes place during direct,

straight pumping. The angle adapt-

er (

11) and the backflow stop-

per (

10) may reduce output.

To increase pump output, the backflow

stopper (10) may be taken out of the angle

plug connections in an area that is safe

from flooding.

• Ensure that the mains voltage matches

the specifications on the rating plate.

• The electrical installation shall be ac-

cording to national wiring rules.

• Connect the equipment only to a sock-

et with a residual current protection

device (residual current circuit breaker)

with a rated current of not more than

30 mA; minimum fuse 6 amperes.

• Before each use, check the equipment,

cable and plug for damage. Defec-

tive cables are not to be repaired, but

rather replaced by new ones. Have

damage on your equipment repaired

by an authorised specialist.

• If the power cable for this equipment is

damaged, it must be replaced by the

manufacturer, a customer service agent

of the same or a similarly qualified per-

son in order to prevent hazards.

• Do not pull the plug from the socket by

the cable. Protect the cable from heat,

oil and sharp edges.

• Do not carry or fix the equipment by

the cable.

• Use only extension cables that are pro-

tected from spray water and designed

for outdoor use. Always fully unroll a

cable drum before use. Check the ca-

ble for damage.

• Disconnect the mains plug from the

socket before all work on the equip-

ment, in case of leaks in the water sys-

tem, during work breaks, and when not

in use.

• The cross-section of mains connection

lines must be no smaller than rub-

ber hose lines with the designation

H07RN-F. The line must be 10 m long.

The flexible lead cross-section of the ex-

tension cord must at least 2.5 mm

2

.