Faults - Causes - Remedies

Faults

Causes

Remedies

Pump does not start

- Mains voltage is not applied

- Float switch (

6) does not

switch

- Check mains voltage

- Bring float switch into higher

position

Pumps has no dis-

charge

- Base (

4) inlet grating

blocked

- Reduces pump performance,

through severely contami-

nated water and additions in

the water which produce a

grinding effect

- Backflow stop (

10) is

incorrectly fitted or faulty

- Use a water jet to clean the

base inlet grating

- Clean pumps and replace

sealing ring (

13) as nec-

essary

- Check the backflow stop’s

connection. Change it if

necessary (see “Maintenance

and Cleaning”)

Pump does not switch

off

- Float switch cannot drop

- Set up pumps correctly on the

pit base

Flow rate insufficient

- Base (

4) inlet grating

blocked

- Reduces pump performance,

through severely contami-

nated water and additions in

the water which produce a

grinding effect

- Backflow stop (

10) is

incorrectly fitted or faulty

- Backflow stop (

10) re-

duces pump performance

- Use a water jet to clean the

base inlet grating

- Clean pumps and replace

sealing ring (

13) as nec-

essary

- Check the backflow stop’s

connection. Change it if

necessary (see “Maintenance

and Cleaning”)

- Remove the backflow stop

from the angle adapter (

11) (see “Start-up”)

Pump switches off

after a short period

- Motor contactor disconnects

the pumps because of water

pollution that is too severe.

- Water temperature too high,

motor contactor breaks

- Pull out power plug and

clean the pump as well as

shaft

- Note maximum water tem-

perature of 35°C!