Technical data, Operating instructions, Fitting the carry handle – Florabest FGPA 1000 A1 User Manual
Page 8: Fitting the suction hose, Mains connection, Fitting a suction pipe
 
GB
- 8 -
•
The pumping of aggressive liquids (acid, 
alkali, silo seepage, etc.) and liquids with 
abrasive (emerizing) substances (sand) must 
likewise be avoided.
5. Technical data
Mains connection: ...........................230V ~ 50 Hz
Power rating: ..............................................1000 W
Max. delivery rate ................................... 4600 l/h
Max. delivery head .........................................45 m
Max. delivery pressure ...........4.5 bar (0.45 MPa)
Max. suction height ........................................... 7 m
Pressure and suction connector: ..............................
..................... approx. 33.3 mm (R1 female thread)
Max. water temperature................................. 35°C
Sound pressure level L
pA
.................... 72.03 dB (A)
Uncertainty K
pA
.......................................... 3 dB (A)
Peak noise level:
Measured ........................................... 84.62 dB (A)
Uncertainty K
WA
.......................................... 3 dB (A)
Guaranteed ..............................................86 dB (A)
Protection class .........................................................I
Protection type .................................................. IPX4
Weight ............................................................8.9 kg
6. Operating instructions
As a basic principle, we recommend the use of 
a preliminary fi lter and a suction set with suction 
hose, intake cage and non-return valve, in order 
to prevent long priming periods and unnecessary 
damage to the pump as a result of stones and so-
lid foreign bodies.
7. Fitting the carry handle
Fasten the carry handle with the 2 screws 
supplied (see Fig. 2).
8. Fitting the suction hose
Fit the suction hose as illustrated in Fig. 3.
Make sure that the end of the adapter (Fig. 1/
Item 11) with the sealing ring (Fig. 1/Item 12) is 
screwed into the equipment.
9. Mains connection
•
The mains connection needs a 230 V ~ 50 Hz 
shock-proof socket. Minimum 10-amp fuse 
required. Please ensure that the power socket 
is easily accessible.
•
Switch on/off at the built-in switch (see Fig. 
1/Item 2).
•
The motor is protected from overload or blo-
ckage by a built-in temperature monitor. In 
case of overheating the temperature monitor 
automatically switches the pump off. After the 
equipment has cooled down, the pump will 
switch on again automatically.
10. Fitting a suction pipe
•
Screw a suction pipe (min. 19 mm (3/4“) 
plastic pipe with spiral reinforcement) either 
directly or with the aid of a threaded nipple 
approx. 33 mm (R1) male thread onto the 
intake line connection approx. 33 mm (R1) 
female thread of the pump (Fig. 1/Item 5).
•
The suction hose should have an intake valve. 
If the intake valve cannot be used then a non-
return valve should be installed in the intake 
line.
•
Position the intake line so that it rises from the 
water withdrawal point to the pump. Avoid 
positioning the intake line higher than the 
pump as this would delay the escape of air 
bubbles from the intake line and impede the 
priming process.
•
Install the intake and discharge lines in such 
a way that they do not exert any mechanical 
pressure on the pump.
•
The intake valve should be low enough in the 
water to ensure that the pump will not run dry 
if the water level falls.