Florabest FGPA 1000 A1 User Manual
Page 9
 
GB
- 9 -
•
A leaking intake line will draw in air and 
therefore not draw in any water.
•
Take measures to prevent the intake of foreign 
bodies (sand, etc.). If necessary install a coar-
se filter.
11. Fitting a pressure pipe
•
The discharge line min. 19 mm (3/4“) must 
be connected either directly or with the aid 
of a threaded nipple approx. 33.3 mm (R1) 
female thread to the discharge line connec-
tion approx. 33 mm (R1) female thread of the 
pump (Fig. 1/Item 7) .
•
You can also use a pressure hose of approx. 
13 mm (1/2“) with the relevant couplings. The 
pump rate is reduced when using the smaller 
discharge line.
•
During the priming process, the shut-off 
devices present in the discharge line (spray 
nozzles, valves, etc.) must be completely 
open so that the air in the intake line can es-
cape freely.
12. Starting up
•
Place the pump on a firm and level surface.
•
Before starting the pump, it must be securely 
mounted on the surface using the holes in 
the stand (see Fig. 1/Item 3).
•
Fit intake line so that it is ready for use.
•
Fill pump with water at the filler screw (Fig. 1/
Item 6) up to the full point.
•
During the priming process, the shut-off 
devices present in the discharge line (spray 
nozzles, valves, etc.) must be completely 
open so that the air in the intake line can es-
cape freely.
•
The initial intake process can take approx. 30 
seconds to 5 minutes, depending on the suc-
tion height and volume of air in the intake line. 
The pump should be topped up with water if 
the priming time is longer.
•
If the pump is removed after use, it is essential 
that it is filled with water again the next time it 
is connected and started.
•
Establish electrical connection.
13. Cleaning and maintenance
•
The pump is largely maintenance-free. In or-
der to ensure a long service life, however, we 
recommend regular checks and product care. 
Caution! 
The pump must be disconnected from 
the power supply by removing the 
power plug before carrying out any 
maintenance.
•
Before lengthy periods of inactivity or winter 
storage rinse the pump thoroughly, empty it 
completely and store it in a dry place.
•
To drain the pump housing, undo the water 
drain screw (Fig. 1/Item 4) and tilt the pump 
slightly.
•
The pump must be completely emptied if there 
is a risk of frost.
•
After relatively long periods of storage, switch 
on and off briefly to check whether the rotor is 
turning properly.
•
If the pump is clogged, connect the discharge 
line to the water line and disconnect the in-
take line. Open the water line. Switch on the 
pump several times for approx. two seconds. 
This should resolve the majority of clog-rela-
ted problems.
•
We recommend lukewarm water to clean the 
motor and pump housing.
14. Replacing the mains cable
Caution!
Disconnect the unit from the power sup-
ply! A defective mains cable may only be 
replaced by a qualifi ed electrician.
Anleitung_4180303.indb 9
Anleitung_4180303.indb 9
21.09.12 10:44
21.09.12 10:44