NOTE: When ordering parts always give the serial and model numbers shown on the boiler and burner.

Refer to Models F3 & F5 Installation Manual, Riello 40 Series Residential Oil Burners (C6501010) or Model F10
Installation Manual, Riello 40 Series Residential Oil Burners
(2902554) for an exploded view of the burner and a list of spare
parts.

RIELLO OIL BURNER PART NUMBERS FOR CL SERIES BOILERS

For replacement Riello oil burner parts, contact your wholesaler or the burner manufacturer:

Riello Corporation of America

35 Pond Park Road

Hingham, Massachusetts 02043

Telephone: (617) 749-8292

Facsimile: (617) 740-2069

Toll Free: (outside Massachusetts)

(800) 992-7637

Riello Canada Inc.

2165 Meadowpine Blvd.

Mississauga, Ontario L5N 6H6

Telephone: (905) 542-0303

Facsimile: (905) 542-1525

Toll Free: (800) 387-3898

TABLE A: RIELLO BURNER SPECIFICATIONS

Boiler

Model

Firing

Rate

GPM

Burner

Model

Settings

Nozzle

Pump

Pressure

Combustion

Head

Insertion

Depth

Air Shutter

Turbulator

GPH x Angle

Type

Shipped

CL3-105

0.75

40F5

2.60

0

0.60 x 60A

(Delavan)

Loose

150

SBT 6.0”

2-3/8”

CL3-140

1.00

2.85

2

0.85 x 60W

(Delavan)

Installed

CL4-175

1.25

40F5

4

4

1.00 x 60A

(Delavan)

Installed

SBT 6.0”

2-3/8”

CL4-210

1.50

40F10

3

1

1.25 x 60B

(Delavan)

Installed

SBT 5.0”

2-1/2”

CL5-245

1.75

40F10

3

1.5

1.35 x 45B

(Delavan)

Loose

SBT 5.0”

2-1/2”

CL5-280

2.00

3.8

2

1.65 x 45B

(Delavan)

Installed

Advertising