Preparing for installation, Verify package contents, Gas supply requirements – Electrolux E30DF74EPS User Manual

Page 7: Gas and electric requirements table

Advertising
background image

7

Preparing for Installation

VERIFY PACKAGE CONTENTS

• Use & Care Manual

• Burner Rings

• Broiler Pan/Insert

• Wok Ring

• Anti-tip Bracket

• Simmerplate

• Grate Pack

• Stainless Steel Cleaner

• Griddle

• Roasting Rack

• LP Conversion Kit

• Burner Cap Pack

GAS SUPPLY REQUIREMENTS

Check your local building codes for the proper method of installation. In the
absence of local codes, this appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1. Be certain that the appliance being installed
is correct for the gas service being provided. Refer to the rating label located on the
kick panel and/or the table below for gas supply requirements.

GAS AND ELECTRIC REQUIREMENTS TABLE

Refer to the following table for more information on gas and electric requirements.

Model No.

Electrical

circuit

required

Total

connected

load

Gas type

Manifold

pressure

Minimum gas

supply

pressure

E30DF74EPS

240-4

Wire VAC,

60Hz, 30A

26.4 Amps

(6.3 Kw)

Natural

Natural

Natural

4” Water Column

4” Water Column

4” Water Column

5” Water Column

5” Water Column

5” Water Column

E48DF76EPS

E36DF76EPS

240-4

Wire VAC,

60Hz, 30A

240-4

Wire VAC,

60Hz, 50A

26.4 Amps

(6.3 Kw)

44.2 Amps

(10.4 Kw)

Liquid Propane 10” Water Column 11” Water Column

Liquid Propane 10” Water Column 11” Water Column

Liquid Propane 10” Water Column 11” Water Column

NO

NO

NO

NO

NOTE

TE

TE

TE

TE

This range is shipped from the factory pre-set for use with natural gas. For LP
conversion see the accompanying LP Conversion Kit. The electrical information in the
table is also located on the serial number label on the range. It can be found by
opening the oven door and looking through the inlet air cooling grill.

Advertising