Start, Destructive surface analysis – Epson 386SX User Manual

Page 243

Advertising
background image

To

start

this test, select

2-Destructive surface

analysis

from the Hard Disk Format Menu. You see these

messages:

Analyze Hard Disk

<Drive 1:>

Read/Save/Write/Read/Restore/Read

check for all tracks...

Current cylinder is nnnn

As the program checks each track, it counts the cylinder

numbers (nnnn) down to zero. When the test is complete, the
program displays a report on the status of the disk, including

a

table of unflagged tracks that produced write, read errors-such
as the following:

Analysis finished.

Count of tracks flagged bad

n

Count of tracks with write, read errors

=

n

Count of good tracks

= nnnn

No write,

read error was detected.

No data was destroyed.

Press ENTER to return to the menu.

If the program finds one bad track that is not flagged, the

summary would show one track with a write, read error. The
report is followed by a table like this:

Write,

Read Error Tracks

Cylinder Head

Cylinder Head

C y l i n d e r

H e a d

Cylinder Head

I

Confirm to register the tracks in the

Read Error Track

as

tracks.

Do you want to register the

tracks as bad tracks?

Physically Formatting a Hard Disk

D-11

Advertising