Precision Digital PD562 User Manual

Page 7

Advertising
background image

1.1 SPECIFICATIONS

General

DISPLAY

Dual 4 digits, red LED, -1999 to 9999

DIN Sizes

PV Display

SP Display

Weight

mm (inch)

mm (inch)

g (oz)

1/8

19.8 (0.78)

11.5 (0.45)

306 (10.6)

1/4

20.5 (0.81)

11.0 (0.43)

389 (13.7)

FRONT PANEL

1/8 DIN: IP65; 1/4 DIN: IP55

SAMPLING TIME

250 ms

OVERRANGE

Over range PV reads ovR, under range PV reads -ovR

PROGRAMMING

Four front panel buttons, Modbus

METHODS

NOISE FILTER

Programmable from 1 to 120

CALIBRATION

All ranges are calibrated at the factory

MAX/MIN

Max/min readings reached by the process are stored until

DISPLAY

reset by the user or until power to the meter is turned off.

PASSWORD

Programmable password restricts modification of
programmed settings

POWER

100-240 VAC, 50/60 HZ, 10 W atts

FUSE

Required fuse: UL Recognized, 1 A, 250 V, slow blow

ISOLATION

2300 V input-to-output-to-power line;
4 kV relay output-to-input/output/power line

ENVIRONMENTAL

Operating temperature range: 10ºC to 50ºC (50ºF to 110ºF)
Relative humidity: 20 to 90% non-condensing

MOUNTING

1/8 or 1/4 DIN size cutout required
Two panel mounting bracket assemblies provided

WARRA NTY

Three years parts and labor

EXTENDED

Extended parts and labor warranties are available at time of

WARRA NTY

ordering

Retransmitting Output

OUTPUT RANGE

Retransmitting: 4 to 20 mA (600

Ω maximum)

SCALING RANGE

Any display range (see range for the input selected)

ACCURACY

+0.1% of full scale

Except where noted all specifications apply to operation at 23ºC.