CALENDAR/CLOCK

RPC-2300

Page 21

Figure 7-1 Calendar/clock installation

DESCRIPTION

The SBS-2300 has a battery backed Calendar/clock
option using the DS-1216EM. When used in conjunction
with the D ATE $ and TIM E$ com mands, the curr ent date
and time c an be set and r ead. The D S-1216E M is
accurate to 1 m inute/mon th at 25°C. Battery life is a
minimum of 5 years.

INSTALLATION

The real time clock is installed in socket U3. Remove
the IC in U3. Install the DS-1216EM in U3. Install the
IC previously removed on top of the DS-1216EM.

SETTING DATE AND TIME

The clock must be turned on before it is used. This need
be done only once. To turn on the clock, type:

CONFIG CLOCK ON

The date and time can be set while running a program or
in the immediate mode. Date and time are treated as
strings and not numbers. T o set the date and time:

date$="08-18-94"
time$="13:56:00"

T o r et r ie v e d a te a nd ti m e a s pa r t o f a p r o gr a m :

2000 DA$ = DATE$(0)
2010 TI$ = TIME$(0)

You can also print the d ate and time in the imm ediate
mode:

pr time$(0)
13:56:03

COMMANDS

The following is a list of CAMBASIC II com mands for
the calendar/clock.

Comm and

Function

DATE$

Sets date

DAT E$(0)

Return s date

TIME$

S e ts ti m e

TIME $(0)

R e tu r n s t im e