CHAPTER 8

ANALOG I/O

RPC-2300

Page 25

0 - 10

value= V * 409.5

± 5V

value= V * 409.5 + 2047.5

The result of the formula produces a number which can
be used in place of value.

COMMANDS

The following is a list of CAMBASIC II com mands for
analog input an d output.

Comm and

Function

CON FIG AIN

Configures analog input

AIN

Returns result of reading

AOT

Sends number to D/A converter