RIGOL DP832 User Manual

Page 139

Advertising
background image

Chapter 5 Specifications

RIGOL

DP800 User’s Guide

5-3

OVP/OCP
Accuracy ±(Output Percentage+Offset)

0.5%+0.5V/0.5%+0.5A

Voltage Programming Control Speed (1% within the total variation range)

Channel

Rise

Fall

Full Load

No Load

Full Load

No Load

DP832

CH1

CH2

CH3

<50ms

<50ms

<15ms

<33ms

<38ms

<14ms

<46ms

<46ms

<24ms

<400ms

<400ms

<100ms

DP831

CH1

CH2

CH3

<18ms

<33ms

<35ms

<17ms

<36ms

<42ms

<20ms

<44ms

<45ms

<200ms

<400ms

<400ms

DP821

CH1

CH2

<110ms

<15ms

<30ms

<15ms

<110ms

<20ms

<800ms

<400ms

DP811

CH1

<45ms

<42ms

<51ms

<1089ms

Temperature Coefficient per (Output Percentage+Offset)
Channel

Voltage

Current

DP832

CH1

CH2

CH3

0.01%+5mV

0.01%+5mV

0.01%+2mV

0.01%+2mA

0.01%+2mA

0.01%+2mA

DP831

CH1

CH2

CH3

0.01%+2mV

0.01%+2mV

0.01%+2mV

0.02%+3mA

0.02%+3mA

0.02%+3mA

DP821

CH1

CH2

0.01%+3mV

0.01%+3mV

0.02%+3mA

0.02%+3mA

DP811

CH1

0.01%+3mV

0.02%+3mA

Stability

[3]

±(Output Percentage+Offset)

Channel

Voltage

Current

DP832

CH1

CH2

CH3

0.02%+2mV

0.02%+2mV

0.01%+1mV

0.05%+2mA

0.05%+2mA

0.05%+2mA

DP831

CH1

CH2

CH3

0.03%+1mV

0.02%+2mV

0.02%+2mV

0.1%+3mA

0.05%+1mA

0.05%+1mA

DP821

CH1

CH2

0.02%+1mV

0.02%+1mV

0.1%+1mA

0.1%+1mA

DP811

CH1

0.02%+1mV

0.1%+1mA

Advertising