Thermo Pride OH5-85DE User Manual

Page 4

Advertising
background image

All installations and services must be performed by qualified service personnel.


OH SERIES

MODEL NO.

OH2

OH5-85

OH11-105

OH5-85DXE

HEAT INPUT RATE IN BTU/HR

70,000 106,250 126,000

85,000
106,250

HEATING CAPACITY IN BTU/HR

56,000 85,000 101,000

74,000
85,000

HEIGHT OF CASING

52” 56”

59-1/2” 56”

WIDTH OF CASING

19” 24” 24” 24”

DEPTH OF CASING

27” 33” 34” 33”

WARM AIR OUTLET

17 x 17

22 x 20

22 x 20

22 x 20

RETURN AIR INLET

18 x 14

23 x 14

25 x 16

25 x 16

DIA. OF FLUE OUTLET

5” 6” 6” 6”

FLOOR-CENTER OF FLUE

TOP TOP TOP TOP

FLOWRATE from .2” & .5” w.c.
EXTERNAL STATIC PRESSURE

COOLING COOLING COOLING COOLING

@2 TON SWITCH SELECTION (CFM)

800 800 800 726

@2-1/2 TON SWITCH SELECTION (CFM)

1000 1000 1000 924

@3 SWITCH SELECTION (CFM)

1200 1200 1200 1276

@3-1/2 TON SWITCH SELECTION (CFM)

1400 1400 1400 1474

4 TON

1600

HEATING HEATING HEATING HEATING

@70deg SWITCH SELECTION (CFM)

737 1134 1335

905
1121

APPROX TEMPERATURE RISE (°F)

70 70 70

72

70

BLOWER MOTOR HP

1/2 1/2 1/2 3/4

NOZZLE SIZE

.55 .75 .90 .70

NOZZLE SPRAY ANGLE PATTERN

80º Hollow

80º Hollow

80º Hollow

45º W

LARGEST RECOMMENDED
AIR CONDITIONER

3.5 Ton

3.5 Ton

3.5 Ton

4 Ton

SIZE OF FILTERS

20” x 16”

25” x 16”

25” x 16”

20” x 25”

NOTES:
1. Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is

required.

6. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps, for all models).