Thermo Pride OH5-85DE User Manual

Page 6

Advertising
background image

All installations and services must be performed by qualified service personnel.


II. BLOWER CONTROLLER INFORMATION

A. TERMINAL DEFINITIONS & FIELD WIRING

Burner Harness Connector P1

Pin 1 – Limit switch connection.
Pin 2 – 120 VAC Line connection.
Pin 3 – Burner pilot contact.
Pin 4&5 – 120 VAC Neutral connection.
Pin 6 – Burner pilot contact.
Pin 7&8 – From oil primary control.
Pin 9 – Limit Switch Input (LSI).

Field Wiring to Burner

Pilot (Tstat) Neutral Line

Yellow Wires

White Red

T-T terminals

White Black

Harness Wires
Beckett Connections
Riello Connections

T-stat terminals

White Black

Thermostat/Humidistat connections

"C"

Common/ground

"W"

Thermostat call for heat

"R"

24 VAC to thermostat

"G"

Thermostat call for fan

"Y"

Thermostat call for cool

“DEHUM”

Humidistat call for dehumidification (TXV systems ONLY)

Thermostat/Humidistat connections for 2-Stage control

"C"

Common/ground

"W1"

T-Stat call for heat (low fire)

"W

2"

T-Stat call for heat (high fire)

"R"

24 vac to T-Stat

"G"

T-Stat call for fan

"Y"

T-Stat call for cool

“DEHUM”

Humidistat call for dehumidification (TXV systems ONLY)

ECM control outputs

Pin 1 - Speed Common

Pin 4 – Blower Enable

Pin 2 - Speed Output

Pin 5 – COOL Enable

Pin 3 – Motor CFM

Pin 6 – “R” Output

Male quick connect terminals.

"S1-3”

120 VAC Hot

“N1-7”

120 VAC Neutral

“EAC”

Electronic Air Cleaner (120 VAC) connection.

“HUM”

Humidifier connection (120 VAC).

"FAN"

Fan On Signal

“X”

24VAC from transformer.

“C”

24VAC common from transformer.

"CC"

Compressor

Contactor

"CC_COM"

Compressor Contactor Common

4

Advertising
This manual is related to the following products: