Thermo Pride OH5-85DE User Manual

Page 5

Advertising
background image

All installations and services must be performed by qualified service personnel.



OC SERIES

MODEL NO.

OC2-56

OC5-85

HEAT INPUT RATE IN BTU/HR

70,000 106,250

HEATING CAPACITY IN BTU/HR

56,000 85,000

HEIGHT OF CASING

57-1/2” 56”

WIDTH OF CASING

19” 24”

DEPTH OF CASING

27” 33”

WARM AIR OUTLET

17 x 17

16 x 20

RETURN AIR INLET

17 x 17

22 x 20

DIA. OF FLUE OUTLET

5” 6”

FLOOR-CENTER OF FLUE

TOP TOP

FLOWRATE from .2” & .5” w.c.
EXTERNAL STATIC PRESSURE

COOLING COOLING

@2 TON SWITCH SELECTION (CFM)

800 800

@2-1/2 TON SWITCH SELECTION (CFM)

1000 1000

@3 SWITCH SELECTION (CFM)

1200 1200

@3-1/2 TON SWITCH SELECTION (CFM)

1400 1400

HEATING HEATING

@70deg SWITCH SELECTION (CFM)

737 1134

APPROX TEMPERATURE RISE (°F)

70 70

BLOWER MOTOR HP

1/2 1/2

NOZZLE SIZE

.55 .75

NOZZLE SPRAY ANGLE PATTERN

80º Hollow

80º Hollow

LARGEST RECOMMENDED
AIR CONDITIONER

3.5 Ton

3.5 Ton

SIZE OF FILTERS

17” x 10”

20” x 12”

NOTES:
1. Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is

required.

7. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps, for all models).
8. All specifications are subject to change without notice.

3