Amprobe AM-140-A User Manual

Page 21

Advertising
background image

15

Overload protections:

Am-140-a:
µA & mA:
1A/600V, IR 10kA or better, F fuse
A: 10A/600V, IR 100kA or better, F fuse
V: 1050VRMS, 1450VPEAK
mV, , & others: 600 VDC & VAC RMS

Am-160-a:
µA & mA:
0.44A/1000V, IR 10kA or better, F fuse
A: 11A/1000V, IR 20kA or better, F fuse
V, mV, , & others: 1050VRMS, 1450VPEAK

Transient protection:

8kV (1.2/50µS SURGE)

E.M.C.:

Meets en61326-1:2006 (EN55022, EN61000-3-
2, EN61000-3-3, EN61000- 4-2, EN61000-4-3,
EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4- 8, EN61000-4-11)

In an RF field of 3V/m:

Capacitance function is not specified

Other function ranges:

Total accuracy = specified accuracy + 100 digits.
Performance above 3V/m is not specified

Power supply:

Single alkaline 9V battery; neda1604a, jis6am6
or Iec6lf22

Power consumption:

6mA typical

Low battery:

Below approx. 7V

Apo timing:

Idle for 17 minutes

Apo consumption:

55µA typical for am-140-a; 30µA typical for am-
160-a

Dimension:

L186mm x W87mm x H35.5mm (7.3in x 3.4in
x 1.4in); L198mm x W97mm x H55mm (7.8in x
3.8in x 2.2in) with holster

Weight:

390 gm (0.9lb); 500 gm (1.1lb) with holster

Advertising